Home>DNA sequencer
DNA sequencer
Model | Max Output | introduction | |
---|---|---|---|
Voltage(KV) | Power(W) | ||
|
0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.1KV 1.25KV 1.5KV 2KV |
0.5W 1W 2W |
1.Models from 0.1KV to 2kV, 0.5W to 2W 2. Low ripple and noise <5mV p-p 3. high stablity 0.001% per hour 4. low temperature coefficient 0.001%/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.5KV 1KV 1.5KV 2KV 3KV 4KV 5KV 7.5KV 10KV |
2W 2.5W 3W 4W 5W 6W 8W 10W |
1. Models from1kV to 30kV, 10W MAX 2. Low output ripple and noise < 2mV P-P 3. High stability 0.001% per hour 4. Low temperature coefficient 0.001%/℃ 5. Low temperature coefficient of 25 ppm per degree Celsius 6. Arc and Short Circuit Protected 7. External potentiometer or external control voltage to set. 8. Optional RS-232, RS-485 control, address can be set and search 9. Positive or negative output 10. Small size, Low noise, 6 -sided metal shielding 11. OEM customization available 12.CE certification |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Models from1kV to 30kV, 5W, 10W, 20W 2. Low output ripple and noise <0.001% P-P 3. High stability 25ppm per hour 4. Low temperature coefficient 25ppm/℃ 5. Low temperature coefficient of 25 ppm per degree Celsius, optionally 10 ppm. 6. Arc and Short Circuit Protected 7. External potentiometer or external control voltage to set. 8. Optional RS-232, RS-485 control, address can be set and research 9. Positive or negative output 10. Small size, Low noise , six -sided metal shielding 11. CE certification |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Ideal for MASS 2. Input DC24V 3. Models from1kV to 30kV, 5W, 10W, 20W 4. High stability 10ppm/hour,20ppm/8hour,100ppm/1000hour 5. High stability 10ppm/hour,20ppm/8hour,100ppm/1000hour 6. Low output ripple and noise less than 5ppm 7. Arc and Short Circuit Protected 8. External potentiometer or external control voltage to set. 9. Optional RS-232, RS-485 control, address can be set and research 10. Small size, Low noise,6 -sided metal shielding 11. Positive polarity or negative polarity output, OEM customisation available 12. CE certification |
|
20KV 30KV |
10W 15W |
1.DNA sequencer,Electrophoresis 2.Models from20kV to 30kV, 10W,15W 3. Low output ripple and noise ≤ 0.01% P-P 4. High stability 0.01%/8 hours 5. Low temperature coefficient 25ppm/ ℃ 6. Arc and Short Circuit Protected 7. External potentiometer or external control voltage to set. 8. Positive or negative output 9. Small size, Low noise , 6 -sided metal shielding 10.OEM customization available 11. Optional RS-232, RS-485 control, address can be set and research 12. Input DC 24V |
|
0.6KV 1.2KV 2KV 3KV 5KV 7.5KV 10KV 12KV 15KV 20KV 25KV 30KV |
6W 9W 15W 30W 60W 75W 100W |
1. Models from3kV to 30kV, 6W to 100W 2. Low output ripple and noise less than 0.1% P-P 3. High stability 0.01% /8 hours 4. Low temperature coefficient 25PPM/ ℃ 5. Arc and Short Circuit Protected 6. External potentiometer or external control voltage to set. 7. Optional RS-232, RS-485 control, address can be set and research 8. Positive or negative output 9. Small size, Low noise , 6 -sided metal shielding 10. OEM customization available 11. Input DC 24V 12.CE certification |
|
0.005KV 0.012KV 0.015KV 0.024KV 0.036KV 0.048KV 0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.7KV 0.8KV |
7.5W 288W 2000W |
1. 9-channel linear power supply for electron beam applications 2. Global AC input capability: 100/120/220/230/240Vac 3. Output voltages: 5V, 12V, 15V, 24V, 48V, 100V,200V, 300V, 400V, 500V, 600V, 700V, customizable 4. Output current: 0.1A to 50A 5. Low output ripple: 3mV 6. ±0.05% output regulation 7. Mean time before failure (MTBF) of 300,000 hours 8. RoHS compliant 9. CE marked in compliance with the Low Voltage Directive 10. Suitable for electron beam, mass spectrometry, and other related applications |